Battery
Charge/Discharge Equipment
We are set for a great leap forward into the global market
with trusted company management, creativity, a challenging spirit and global level of technology.
SF[Small Cell Formation]
![SF[Small Cell Formation] Image](../../../test/master/shop/sang_photo/KORVAC_20150527160528.jpg)
Overview
◆ Formation Line for Li-ion cell or other type of cell
◆ Current ranges: 100mA~600mA
◆ Suitable for the mass production line simultaneously operated multi-channels
◆ Automatic production with ONLINE Mode
◆ Interworking between electrical part and automatic, semi-automatic and manual type of Jig part
◆ Accurate and rapid control by real-time control
Functions |
Specifications | |
Application |
Small cell for Bluetooth , etc. | |
Interface |
IEEE802.3(LAN) | |
Control Mode |
CC, CV, CC/CV, OCV | |
PC Software |
CTS series | |
Voltage |
Measurement Accuracy |
±0.05% F.S |
Resolution |
16 bit | |
Current |
Measurement Accuracy |
±0.1% |
Resolution |
16 bit | |
Number of current range per channnel |
Maximum 2Range | |
Control Interval |
500/1000ms | |
Current Rising Time |
< 200ms
(Reached at 10%~80% of the set value) | |
Input Power Supply |
1or 3 Phase 220Vac 50/60Hz |
Specification
Model Designation |
Voltage |
Current |
Max. Number of Channels |
Cabinet Size (W*D*H/mm) |
PESF05-0.2 |
2.5~5V |
200 / 100 mA |
128 / 192 / 256 / 576 |
620*1080*820 |
PESF05-0.6 |
2.5~5V |
600 / 300 mA |
128 / 256 |
650*1200*670 |
* Option: Discharge under 2.5V | ||||
Model.SF can be configured with a wide range of voltage and current ranges and can be fitted with optional hardware to provide a number of additional features and capabilities. | ||||
CF [Cell Formation]
![CF [Cell Formation] Image](../../../test/master/shop/sang_photo/KORVAC_20150527160534.jpg)
Overview
◆ Formation Line for Li-ion cell or other type of cell
◆ Current ranges: 1A~6A
◆ Suitable for the mass production line simultaneously operated multi-channels
◆ Automatic production with MES
◆ Interworking between electrical part and automatic, semi-automatic and manual type of Jig part
◆ Accurate and rapid control by real-time control
Functions |
Specifications | |
Application |
Cell for Mobile , Notebook, Tablet | |
Interface |
IEEE802.3(LAN) | |
Control Mode |
CC, CV, CC/CV, OCV | |
PC Software |
CTS series | |
Voltage |
Measurement Accuracy |
±0.05% F.S |
Resolution |
16 bit | |
Current |
Measurement Accuracy |
±0.1% |
Resolution |
16 bit | |
Number of current range per channnel |
Maximum 3Range | |
Control Interval |
200/500/1000ms | |
Current Rising Time |
< 200ms
(Reached at 10%~80% of the set value) | |
Input Power Supply |
1or 3 Phase 220Vac 50/60Hz |
Specification
Model Designation |
Voltage |
Current |
Max. Number of Channels |
Cabinet Size (W*D*H/mm) |
PECF05-02 |
2.5~5V |
2A |
128 / 256 |
600*1450*490 |
PECF05-03 |
2.5~5V |
3A |
256 |
600*1450*490 |
PECF05-04 |
2.5~5V |
4 / 2 / 1 A |
151 |
600*1450*490 |
PECF05-06 |
2.5~5V |
6 / 3 / 2 A |
128 |
600*1450*490 |
* Option: Discharge under 2.5V | ||||
Model.CF can be configured with a wide range of voltage and current ranges and can be fitted with optional hardware to provide a number of additional features and capabilities. | ||||
CRF [Regenerative Cell Formation]
![CRF [Regenerative Cell Formation] Image](../../../test/master/shop/sang_photo/KORVAC_20150527160530.jpg)
Overview
◆ Formation Line for Li-ion cell or other type of cell
◆ Energy regenerative type
◆ Current ranges: 1A~6A
◆ Suitable for the mass production line simultaneously operated multi-channels
◆ Automatic production with MES
◆ Interworking between electrical part and automatic, semi-automatic and manual type of Jig part
◆ Accurate and rapid control by real-time control
Functions |
Specifications | |
Application |
Cell for Mobile , Notebook, Tablet | |
Type |
Regenerative | |
Interface |
IEEE802.3(LAN) | |
Control Mode |
CC, CV, CC/CV, OCV | |
PC Software |
CTS series | |
Voltage |
Measurement Accuracy |
±0.05% F.S |
Resolution |
16 bit | |
Current |
Measurement Accuracy |
±0.1% |
Resolution |
16 bit | |
Number of current range per channnel |
Maximum 3Range | |
Control Interval |
500ms | |
Current Rising Time |
< 200ms
(Reached at 10%~80% of the set value) | |
Input Power Supply |
1or 3 Phase 220Vac 50/60Hz |
Specification
Model Designation |
Voltage |
Current |
Max. Number of Channels |
Cabinet Size (W*D*H/mm) |
PECRF05-03 |
2.5~5V |
3A |
128 / 256 |
600*1450*490 |
PECRF05-06 |
2.5~5V |
6 / 3 / 2 A |
151 |
1000*900*550 |
* Option: Discharge under 2.5V | ||||
Model.CRF can be configured with a wide range of voltage and current ranges and can be fitted with optional hardware to provide a number of additional features and capabilities. | ||||
BF [Battery Formation]
![BF [Battery Formation] Image](../../../test/master/shop/sang_photo/KORVAC_20150527160537.jpg)
Overview
◆ Formation Line for Li-ion cell or other type of cell
◆ Able to apply for the prismatic type and Pouch type of high power battery cell
◆ Current ranges: 6A~50A
◆ Suitable for the mass production line simultaneously operated multi-channels
◆ Automatic production with MES
◆ Interworking between electrical part and automatic, semi-automatic and manual type of Jig part
◆ Automatic contact function by automation Jig
◆ Accurate and rapid control by real-time control
Functions |
Specifications | |
Application |
High Power Battery for xEV, E-bike | |
Interface |
IEEE802.3(LAN) | |
Control Mode |
CC, CV, CC/CV, OCV | |
PC Software |
CTS series | |
Voltage |
Measurement Accuracy |
±0.05% F.S |
Resolution |
16 bit | |
Current |
Measurement Accuracy |
±0.1% |
Resolution |
16 bit | |
Number of current range per channnel |
Maximum 3Range | |
Control Interval |
500ms | |
Current Rising Time |
< 200ms
(Reached at 10%~80% of the set value) | |
Input Power Supply |
1or 3 Phase 220Vac 50/60Hz |
Specification
Model Designation |
Voltage |
Current |
Max. Number of Channels |
Cabinet Size (W*D*H/mm) |
PEBF05-12 |
2.5~5V |
12 / 6A |
24 / 48 |
660*1450*600 |
PEBF05-24 |
2.5~5V |
24 / 12 / 6A |
24 / 48 |
650*910*1110 |
PEBF05-50 |
2.5~5V |
50 / 25 / 12 A |
24 |
1230*1050*390 |
* Option: Discharge under 2.5V | ||||
Model.BF can be configured with a wide range of voltage and current ranges and can be fitted with optional hardware to provide a number of additional features and capabilities. | ||||
BRF [Regenerative Battery Formation]
![BRF [Regenerative Battery Formation] Image](../../../test/master/shop/sang_photo/KORVAC_20150527160554.jpg)
Overview
◆ Formation Line for Li-ion cell or other type of cell
◆ Energy regenerative type
◆ Current ranges: 10A~200A
◆ Suitable for the mass production line simultaneously operated multi-channels
◆ Automatic production with MES
◆ Interworking between electrical part and automatic,semi-automatic and manual type of Jig part
◆ Accurate and rapid control by real-time control
Functions |
Specifications | |
Application |
High Power Battery for xEV, E-bike | |
Type |
Regenerative | |
Interface |
IEEE802.3(LAN) | |
Control Mode |
CC, CV, CC/CV, OCV | |
PC Software |
CTS series | |
Voltage |
Measurement Accuracy |
±0.05% F.S |
Resolution |
16 bit | |
Current |
Measurement Accuracy |
±0.1% |
Resolution |
16 bit | |
Number of current range per channnel |
Maximum 3Range | |
Control Interval |
500ms | |
Current Rising Time |
< 200ms
(Reached at 10%~80% of the set value) | |
Input Power Supply |
1or 3 Phase 220Vac 50/60Hz |
Specification
Model Designation |
Voltage |
Current |
Max. Number of Channels |
Cabinet Size (W*D*H/mm) |
PEBRF05-10 |
2.5~5V |
10 / 5 / 1A |
32 |
660*1100*550 |
PEBRF05-24 |
2.5~5V |
24 / 12 / 6A |
24 |
650*1050*270 |
PEBRF05-25 |
2.5~5V |
25A / 12.5 / 6.25A |
32 |
630*1100*760 |
PEBRF05-30 |
2.5~5V |
30 / 12 / 6A |
24 |
650*890*680 |
PEBRF05-65 |
2.5~5V |
65 / 30 / 15A |
24 |
900*600*740 |
PEBRF05-100 |
2.5~5V |
100A |
16 |
|
PEBRF05-150 |
2.5~5V |
150A |
16 |
1650*1100*520 |
PEBRF05-200 |
2.5~5V |
200A |
16 |
|
* Option: Discharge under 2.5V | ||||
Model.BRF can be configured with a wide range of voltage and current ranges and can be fitted with optional hardware to provide a number of additional features and capabilities. | ||||
ACIR /OCV

Overview
ACIR/OCV is for determining R,L and C in cell by measuring OCV and internal resistance of secondary cell and capacitor.◆ | Analyzing the internal resistance of secondary cell and capacitor |
◆ | Evaluating the quality of samples by quickly measuring internal resistance spectrum. |
◆ | Measuring open circuit voltage |
◆ | Grading measurements |
◆ | Measurement frequency fixed (1Khz), frequency selection (Option) Available |
◆ | Providing multiple contacts such as auto/semi- auto/manual contact |
◆ | Measuring time : Single frequency (1KHz) within a few seconds |
◆ | Muli contact point provided is possible to rapidly measure multi channel cell. (Mass production) |
◆ | Variable frequency and current measurement functions can be used as a R&D equipment |
Specification
CUSTOMIZING
CONTACT
PNE SOULTION Sales Dept.
- TEL:
- +82-31-2990-100
- E-MAIL:
- power@pnesolution.com